Description FFJ104: --------------------- Hardware: ---------- Size : 150 mm X 124 mm 4 layer PCB CPU : Hitachi H8s2357 20MHz RAM : External 32kbyte + Internal 8kbyte. EEPROM : External 8kbyte. Flash 1 : 128kbyte internal for program. Flash 2 : 512kbyte external for Datalogger memory. Input/output: ------------- USB Bus : National USBN9602 for PC datalogger access. CAN Bus : Philips SJA1000 with resistor network driver. PC interface : RS232 at the internal 10pin connector. Diagnose : ISO9141 with K and L-line. Inputs: -------- Water temperature : Standard Bosch 2kohm@20deg NTC, -30-->120deg range Air temperature : Standard Bosch 2kohm@20deg NTC. -30-->120deg range Trottle prosition : 0.0V-->5.0V or 5.0V-->0.0V Manifold or Airmass 0.0V-->6.0V differential input. Lambda : 0.0V-->5.0V standard lambda sonde. Knock in : 2 pcs Knock input. Crank chaft sensor: Inductive or Hall dependant on jumper setting. Intake CAM sensor : Inductive or Hall dependant on jumper setting. Speed sensor 1 : Hall sensor for drive wheels. Outputs: --------- Injectors : 6 pcs minimum 3 Ohm injector outputs (or 8 if Idle/EGAS not used) Ignition : 6 pcs 9 Amps-450 Volts KL1 ignition outputs Idle/EGAS : EGAS H-Bridge 15A or 3/2 pole Idle regulator output Intake CAM Adjust : 1A Low side drive (BMW). Wastegate control : 1A Low side drive. Evap : 1A Low side drive. Fuel pump : 1A Low side drive. Main relay : 1A Low side drive. RPM output : 50V fly back. Reference : 1 pcs. 5.0V